79 01202 662500 | sales@hamworthy-heating.com | hamworthy-heating.com Horton dosing pot Facilitates safe insertion of liquid chemicals into a sealed heating system. Used for liquid chemical dosing of corrosion inhibitors to continually protect your boiler plant from dirty system water. Key benefits: Carbon steel pipe body and tundish with brass valves Simple and safe to operate without needing to drain down the system Easy to isolate and flush clean Working pressure up to 14 bar 4 Models Capacities of 3.5-15 Litres Note: All dimensions in mm. Note: For guidance on sizing please refer to page 97. Dimensions Horton product code Installed boiler output (kW) Maximum system volume (litres) HN-3.5 0-250 0-2499 HN-5 250-500 2,500-4,999 HN-10 500-1000 5,000-9,999 HN-15 1,000 and above 10,000 and above 1” BSP Ball valve (Dose isolation) 1” BSP Non-return valve 1” BSP Ball valve (System return) 1/8” BSP nipple Mounting brackets Tundish 1/8”Air vent 1” BSP Ball valve (Drain) 1” BSP Ball valve (System Flow) MODEL HN-3.5 284 Ø B Ø115 100 A C 198 1” BSP Ball valve (Dose isolation) 1” BSP Non-return valve 1” BSP Ball valve (System return) 1/8” BSP nipple Mounting brackets Tundish 1/8”Air vent 1” BSP Ball valve (Drain) 1” BSP Ball valve (System flow) C 284 Ø B Ø115 A 198 100 MODELS HN-5, HN-10 & HN-15 Dimension Reference HN-3.5 HN-5 HN-10 HN-15 Overall width A 265 265 315 315 Diameter B 166 168 219 219 Body height C 186 258 293 446 Technical data ADDITIONAL PRODUCTS